电生理工作站 -金沙1005

上海玉研科学仪器有限公司

电话:021-35183767
   021-54377179

传真:021-35183767-8008

qq:2113136797

地址:上海市闵行区兴梅路485号 xingmei rd 485,shanghai,china

当前位置: > 生理信号测量 > 电生理工作站
生理信号测量

电生理工作站

时间:2016-09-14来源:本站作者:玉研仪器

详细介绍

电生理工作站是一款多功能细胞外记录终端。以精致和实用性为设计理念,为研究人员提供了一个强大的电子数据记录工具。配合控制软件neuro-guide使用,aris可以为您提供了体内电生理学工作站。将电极连接到系统上即可开始您的电生理学实验。


电生理工作站aris具备两个独立的操作模式:电脑模式和手动模式。包括下列硬件单元:放大器、放大器、过滤器、刺激发生器、阻抗测量、数据采集模块。

 

电生理工作站aris的主要特征:
4通道记录系统
集成探头
spikes,局部场电位(lfp)
微硬盘
数据采集
spike sorting
图谱集成

 

aris – electrophysiology workstation

aris is a multifunctional hardware solution for extracellular recording. it was designed with compactness and utility in mind to offer the researchers a powerful electronic tool.

aris offers a state-of-the-art workstation for in-vivo electrophysiology.


all in one

  • amplification, conditioning and acquisition of neuronal signals
  • programmable current stimulus generator
  • impedance measurement module

aris perfectly integrates in a computerized laboratory setting, and can also be used only as a companion tool in a hardware-exclusive recording or stimulation arrangement. accordingly, it offers two independent operation modes: pc-control and manual.

aris incorporates even the preamplifier module and connects directly to a laptop or desktop computer.

computer controlled electrophysiology research

this equipment was designed especially for optimal amplification and acquisition of extracellular neuronal signals: single-unit potentials (2 channels) and local field potentials (2 channels). the integrated data card ensures full computer control: channel selection, switching of operation modes (recording, stimulation, impedance), programmable generation of stimulus waveforms of amplitudes up to 1ma @ 250v.

clean signal

the differential input recording channels were designed with care to guarantee maximal immunity to environmental noise. the steep response of the 4th order low-pass and high-pass filters were optimally pre-tuned to ensure a virtually hands-free operation.

direct impedance test

measurement of microelectrode impedances up to 2mw is realized on-the-fly based on the voltage feedback of the 1na sinusoidal signal sent to the preparation.

computer controlled stimulation current

the stimulation current is precisely generated by the data card with no additional processing burden on the connected computer. repetitive current pulse trains or lesioning/marking constant current are supported.

no cable reconnection

aris is capable of no-electrode-touch switching of operation modes: recording, stimulation, impedance testing. that is, the same preparation cable remains in place during the entire experiment.

fully computer controlled or stand-alone

when operated through your laptop or desktop computer via the neuro-guide software, aris employs not more than three connectors and cables (preparation connections and computer connection), and no other frontal panel auxiliaries. actually, aris was designed for full flexibility, being able to operate in two independent modes: “pc-control”, and “manual”. switching from manual to pc-control is realized automatically when the computer cable is connected, and this condition is indicated by a frontal led. this allows reusing your existing laboratory equipment in various combinations, for instance:

  • transforming an external ttl signal into a stimulation current deliverable by aris,
  • using aris as a programmable stimulus generator only,
  • using aris for signal amplification and conditioning only,
  • generating lesioning/marking current directly from aris’s frontal panel, etc.



    您想了解更多详细资料吗?

    请与我们联系:

    tel021-35183767021-54377179

         18502129044

    qq973365933

    微信:yuyanbio

    mail

    欢迎您的咨询!


网站地图