显微镜温度控制器 -金沙1005

上海玉研科学仪器有限公司

电话:021-35183767
   021-54377179

传真:021-35183767-8008

qq:2113136797

地址:上海市闵行区兴梅路485号 xingmei rd 485,shanghai,china

当前位置: > 细胞培养及分析设备 > 显微镜温度控制器
细胞培养及分析设备

显微镜温度控制器

时间:2016-10-02来源:本站作者:玉研仪器

详细介绍

h401-t-controller 显微镜温度控制器

 

2-channel temperature controller with 4.3'' touch screen interface compatible with all h401 heating devices. one controller can control independently up to two items.

external temperature sensor (included) and self calibration routines allows easy calibration of the heating devices for the highest accuracy on sample temperature.

on board data logging and download procedures to usb drives allow to record temperature as a function of time and to log calibration events and alarms.

the controller is equipped with password protected routines to re-calibrate the sensors against certified thermometers.

 

features

t - range: from ambient to 60°c
t - accuracy on specimen: ± 0.3°c
external t - sensor (included).
on-board data logging and download routines to usb drive. 
on-board logging of calibration and alarm events.
alarm buzzer and external alarm connector
one controllers can control independently up to two devices.
self calibration routines allow to improve temperature accuracy.
password protected procedure for periodic calibration against certified thermometer
integrated in third party software: nikon nis elements; metamorph; micromanager

 

h401-t-pad

the heated flat metal plate can be positioned on any surface (table top, cabinet work surface, etc) to create a temperature controlled flat surface.

 

features

t range: 27 to 45°c

t sensor accuracy: ±0.1°c

t accuracy on specimen: ±0.3°c, after self calibration, if room temperature remains within ±1°c

plate calibration can be performed in the lab by the operator

dimensions:

174x234 mm        h401-t-pad-small
297x210 mm (a4) h401-t-pad-medium
420x300 mm (a3) h401-t-pad-large
 

h401-glass table

the ito glass table realizes a flat and transparent surface at controlled temperature. ideal for stereo microscopes.

it requires h401-t-controller.

 

features

t range: ambient to 60°c
t sensor accuracy: ±0.1°c
t accuracy on specimen: ±0.3°c, after self calibration, if room temperature remains within ±1°c
4.3'' touch screen interface
on-board data logging and download routines to usb drive
plate calibration can be performed in the lab by the operator
glass thickness: 2 mm
adjustable height:
from 31 to 37 mm
from 75 to 105 mm

 

 

 

h401-k-frame-metal-glass

the glass side of the metal glass t plate creates a warm and optically transparent surface perfectly flush with the microscope stage. it employs indium tin oxide (ito) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. the glass is chemically strengthened and protected by a rigid aluminum frame.

the metal side of the metal glass t plate features a trimmed 24 mm diameter observation opening for imaging with oil immersion lenses.

the metal and glass sides have independent temperature sensors for independent temperature control of each side.

it requires h401-t-controller. uses both channels. 

features

flush with stages with k-frame insert (160x110mm), compatible with the following xy stage: marzhauser (all models), ludl (all models), asi (all models, including z-piezo), prior h107 and h117, leica (k-frame), zeiss (k-frame), olympus (k-frame)
temperature range: from ambient to 60°c
accuracy on specimen: ± 0.3°c
4.3'' touch screen interface
on-board data logging and download routines to usb drive
ito glass side thickness: 0.5 mm, chemical glass strengthening ensures highest resistance
easy plate replacement, if necessary
flat respect to the rest of the xy stage
uses both channels of the dual controller h401-t-controller

 

h401-k-frame-metal-flat

the metal t plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. it employs a surface sensor to ensure the highest accuracy on temperature reading.

 

 

h401-nikon-ti-s-er-metal

the metal t plate creates a warm flat temperature controlled surface at the same height as the rest of the xy stage perfectly flush with the microscope stage. it employs a surface sensor to ensure the highest accuracy on temperature reading.

 

 

full stage heater

the stage heater covers the entire xy stage and provides a flat, smooth surface at controlled temperature. it clamps on the stage and it is fixed in place by set crews positioned on the vertical sides of the plate. the stage heater leaves the observation hole open.

it is possible and recommendable to use the stage heater in combination with glass heated insert. in this configuration, the h401-t-controller uses one channel to control the metal pad and the other channel to control the glass insert. models available for nikon and olympus stages.

it requires h401-t-controller.

features

clamps on the stage and creates a flat surface at constant t
temperature range: from ambient to 45°c
accuracy: ±0.3°c
4.3'' touch screen controller
on-board data logging and download routines to usb drive
compatible with glass plates
easy to fix on stage
models available for:
nikon-ti-sr               (code h401-nikon-ti-sr-t-pad)
nikon-ts2r                (code h401-nikon-ts2r-t-pad)
olympus-ix-susp       (code h401-olympus-ix-susp-t-pad)

 

 

 

    您想了解更多详细资料吗?

    请与我们联系:

    tel021-35183767021-54377179

         18502129044

    qq2113136797

    微信:yuyanbio

    mail

    欢迎您的咨询!

网站地图